Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
812 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1. Enter these commands in order: busyout boardreset boardrelease board.  
The board reset is required to reload on-board RAM associated with the TN744’s DSPs.  
This takes all 8 Tone Detector ports out of service for a few seconds.  Only 4 of the 8 
would be out of service due to the alarm.  (There are five Tone Detectors on each of the 
two DSPs.) Other than the unlikely potential of running out of Tone Detector resources in 
the switch, there is no other effect when the board is reset.
2. Test the board with test board location long.
3. If the test still fails, replace the board.
b. Error 257: The CLSFY-PT lost its translation.  Testing the CLSFY-PT is sufficient to reload 
its translation.  If testing the call classifier port does not clear the error, then the call 
classifier circuit pack containing the defective call classifier port should be replaced.
c. Error 513: This error indicates the call classifier port is having problems detecting call 
classification tones or detecting and generating R2-MFC tones This is usually accompanied 
by failures of some incoming or outgoing calls.  If this error type is persistently logged, then 
replace the call classifier circuit pack containing the defective CLSFY-PT.
System Technician-Demanded Tests:
Descriptions and Error Codes
Investigate tests in the order presented.
Tone Detection Verification Test (#42)
This test checks the operation of the TN744 in touch-tone receiver, call classifier and R2-MFC 
modes.  It verifies the circuit pack’s ability to detect DTMF, ring back, busy reorder and modem 
answer tones and to generate and detect forward and backward MFC tones.
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
Tone Detection Verification test (#42)
X
X
ND
Tone Detection Audit/Update test (#43)
X
X
ND