CLSFY-PT (Call Classifier Port)
Issue 1 June 2005
813
 
Table 279: Test #42 Tone Detection Verification Test 
Error 
Code
Test 
Result
Description / Recommendation
none
ABRT
The system was not able to allocate every resource needed for this test, 
OR there was an internal system error.
1
ABRT
The system could not allocate every resource needed to test the tones.
1. Retry the command at 1-minute intervals up to 5 times.
1001
ABRT
The system was unable to put the call classifier port in the appropriate 
mode to test it.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABRT
The system could not allocate time slots for the test connection.  This 
situation could occur when the system is heavily loaded.  If the system is 
not heavily loaded, use test tdm to test the TDM-BUS.
1. Retry the command at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a Tone-Clock for the test connection.  This 
may be caused by a heavy load on the system or by a faulted Tone-Clock.
1. Check to see if there are any alarms against the Tone-Clock in the PN 
where the test aborted.  If so, se
recommended procedures.
2. If a new Tone-Clock has been inserted, allow about 1-minute for 
maintenance to run on the newly inserted circuit pack.
3. Retry the command at 1-minute intervals up to 5 times.
2000
ABRT
Call classifier circuit pack’s response to the test request was not received 
within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.