Communication Manager Maintenance-Object Repair Procedures
814 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
2006
ABRT
Indicates that the active Tone-Clock circuit pack or a Tone Detector circuit 
pack may not be functioning properly.
If there is more than one Tone Detector circuit pack in the system, then 
the problem can be either with the Tone-Clock circuit pack or the Tone 
Detector circuit pack. This could also be caused by the mode 
administered for the system not matching that of the Tone Detector circuit 
pack.
1. Test the active Tone-Clock circuit pack in the PN with test 
tone-clock UUC.  See 
2. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1-3
FAIL
DTMF digits were not detected correctly.  This may or may not impact 
reception of R2-MFC calls.
1. Run the short test sequence via test port location sh r 1.
2. If the problem persists, the system is still operating properly but 
capacity will be reduced.  To restore performance to normal, replace 
the call classifier circuit pack containing the defective CLSFY-PT (Call 
Classifier Port).
S8700 | 
8710
 
S8500
 
102
FAIL
2225-Hz Modem Answer tone was not detected correctly.  This will impact 
call-classification operation.
1. Run the short test sequence with test port location sh r 1.
2. If the problem persists, the system can still operate properly but 
capacity will be reduced.  In order to restore performance to normal, 
replace the call classifier circuit pack containing the defective port.
101-
122 
130  
FAIL
Forward or backward R2-MFC signals were not correctly generated or 
detected.  This will impact R2-MFC calls.
1. Run the short test sequence with test port location sh r 1.
2. If the problem persists, the system can still operate properly but 
capacity will be reduced.  In order to restore performance to normal, 
replace the call classifier circuit pack containing the defective port.
PASS
Tone detection verification is successful.  The call classifier port is able to 
detect and generate every necessary tone.
Table 279: Test #42 Tone Detection Verification Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2