Communication Manager Maintenance-Object Repair Procedures
818 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
S8300
 / 
G700
The MM710 supports T1/E1, and delivers the same functionality as the TN464 circuit pack. 
Although  CO-DS1 is provided for G700/G350 Media Gateways, CO-DS1 only partially supports 
the MM710 DS1 Media Module.
Three trunk service states are specified by DS1 CO trunk maintenance:
Error Log Entries and Test to Clear Values
out-of-service
The trunk is in a deactivated state and cannot be used for either 
incoming or outgoing calls.
in-service
The trunk is in an activated state and can be used for both 
incoming and outgoing calls.
disconnect 
(ready-for-service)
The trunk is in an activated state but can only be used for an 
incoming call.
Table 281: DS1 CO Trunk Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
)
0
Any
Any
Any
test trunk grp/mbr
)
57408
)
57487
Any
Port Audit and Update (#36)
0
busyout trunk grp/mbr
WRN
OFF
release trunk grp/mbr
130 (
None
WRN
ON
test trunk grp/mbr
257 (
57392
DS1 CO Dial Tone Seizure (#314) 
G700
 aborts with Error Type 1412
MIN
WRN
OFF
513 (
57393
DS1 CO Dial Tone Seizure (#314) 
G700
 aborts with Error Code 1412
MIN 
WRN
OFF
769 (
57484
1025
DS1 CO Dial Tone Seizure (#314) 
G700
 aborts with Error Code 1412
MIN 
WRN
1
OFF
test trunk grp/mbr r 2
1281
Conference Circuit  (#7) 
G700
 aborts with Error Code 1412
MIN 
WRN
ON
test trunk grp/mbr l r 4
1537
NPE Crosstalk  (#6) 
G700
 aborts with Error Code 1412
MIN 
WRN
ON
test trunk grp/mbr l r 3
 1 of 2