Avaya 03-300430 User Manual

Page of 2574
CO-DS1 (DS1 CO Trunk)
Issue 1 June 2005
821
 
System Technician-Demanded Tests: Descriptions and Error 
Codes
Investigate tests in the order they are presented. By clearing error codes associated with the 
NPE Crosstalk test (#6), you may also clear errors generated from other tests in the testing 
sequence.
NPE Crosstalk Test (#6)
Note:
Note:
S8300
 / 
G700
: This test aborts with Error Code 1412.
The NPE Crosstalk test verifies that this port’s NPE channel talks on the selected time slot and 
never crosses over to time slots reserved for other connections.  If the NPE is not working 
correctly, one-way and noisy connections may be observed.  This test is usually only part of a 
port’s long test sequence and executes in about 20 to 30 seconds.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1.  D = Destructive; ND = Nondestructive
NPE Crosstalk test (#6) 
S8300
 / 
G700
 aborts with Error Code 1412
X
ND
Conference Circuit test (#7) 
S8300
 / 
G700
 aborts with Error Code 1412
X
ND
DS1 CO Trunk Seizure test (#314) 
S8300
 / 
G700
 aborts with Error Code 1412
X
X
ND
Port Audit and Update test (#36)
X
X
ND
Table 282: Test #6 NPE Crosstalk Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 4