1020
ABRT
The test did not run due to a previously existing error on the specific port or
a more general circuit pack error.
a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the already existing error.
S8300
G700
1412
ABRT
This test does not execute on a G700 Media Gateway.
2000
ABRT
Response to the test request was not received within the allowable time
period.
period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2053
ABRT
At least one of the following errors was found on the DS1 circuit pack: Loss
of signal (1281), Blue alarm (1793), Red alarm (2049), Yellow alarm (2305),
or Hyperactivity (1537).
of signal (1281), Blue alarm (1793), Red alarm (2049), Yellow alarm (2305),
or Hyperactivity (1537).
1. Look for the previous error types in the Hardware Error Log, and follow
the procedures given in the appropriate DS1-BD or UDS1-BD
maintenance documentation for the listed error types.
maintenance documentation for the listed error types.
FAIL
The NPE of the tested port was found to be transmitting in error. This will
cause noisy and unreliable connections.
cause noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots. User-reported troubles on
this port should be investigated using other port tests and examining station,
trunk, or external wiring.
Table 282: Test #6 NPE Crosstalk Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
3 of 4