Avaya 03-300430 User Manual

Page of 2574
CO-DS1 (DS1 CO Trunk)
Issue 1 June 2005
825
 
Table 283: Test #7 Conference Circuit Test 
Error
Code
Test
Result
Description / Recommendation
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
The test was aborted.  System resources required to run this test were not 
available.  The port may be busy with a valid call.
1. Use display port location to determine the trunk group/member 
number of the port.  Use status trunk to determine the service state 
of the port.  If the port is active, wait until it is idle before testing.
2. If the port status is active but the port is idle (no calls), check the error 
log for error type 1025 (see the error log table for a description of this 
error and required actions).  The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals up to 5 
times.
1002
ABRT
The system could not allocate time slots for the test.  The system may be 
under heavy traffic conditions, or it may have time slots out of service due 
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic 
and the port status is idle, retry the command at 1-minute intervals up 
to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test.  The system may 
be oversized for the number of Tone Detectors present, or some of the 
Tone Detectors may be out of service.
1. Use list measurements tone-receiver to see basic information 
about the system's tone receivers.
2. Resolve any TTR-LEV errors.
3. Resolve any TONE-PT errors.
4. If neither condition exists, retry the command at 1-minute intervals up 
to 5 times.
1004
ABRT
The port has been seized by a user for a valid call.
1. Use status station or status trunk to determine when the port 
is available for testing.
2. Retry the command at 1-minute intervals up to 5 times.
 1 of 4