CO-DS1 (DS1 CO Trunk)
Issue 1 June 2005
829
 
Port Audit and Update Test (#36)
This test sends port level translation data from switch processor to the DS1 Interface circuit 
pack or media module to assure that the trunk’s translation is correct.  Translation updates 
include the following data: trunk type (in/out), dial type, timing parameters, and signaling bits 
enabled.  The port audit operation verifies the consistency of the current state of trunk.
Table 284: Test #36 Port Audit and Update Test 
Error 
Code
Test 
Resul
t
Description / Recommendation
ABRT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test were not available.  The port 
may be busy with a valid call.
1. Enter display port location to determine the trunk group/
member number of the port.  Use status trunk to determine the 
service state of the port.  If the port is active, wait until it is idle before 
testing.
2. If the port status is active but the port is idle (no calls), check the error 
log for error type 1025.  The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals up to 5 
times.
1006
ABRT
The DS1 CO trunk is out of service.
1. Use status trunk to verify that the trunk is out of service.
2. If the trunk is out of service, determine why.
3. If it is OK to put the trunk back in service, enter release trunk to put 
the trunk back in service, and then retry the test.
2000
ABRT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Test failed due to internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 2