CO-DS1 (DS1 CO Trunk)
Issue 1 June 2005
833
 
S8300
 /
G700
  
1412
ABRT
This test does not execute on a G700 Media Gateway.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2012
ABRT
The test was aborted due to an internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources for this test.
1. Retry the command at 1-minute intervals up to 5 times.
2000
FAIL
Response to the seizure message was not received within the allowable 
time period.
1. Enter list configuration board location.  If the circuit pack 
is a TN767B vintage 8 or 9, a failure of test 314 causes a subsequent 
failure of test 7 due to a firmware bug.  Eventually, the board and all of 
its ports will be taken out of service and extraneous on-board alarms 
will be generated.  Replace the circuit pack with a TN767C V3 or later.
2. Verify that the Trunk Type field on the Trunk Administration form 
matches the trunk type administered on far-end switch.
3. Look for DS1-BD or UDS1-BD errors in the hardware error log.  If 
present, see 
4. Retry the command at 1-minute intervals up to 5 times.
2053
FAIL
At least one of the following errors was found on the DS1 circuit pack:  
Loss of signal (1281), Blue alarm (1793), Red alarm (2049), Yellow alarm 
(2305), or Hyperactivity (1537).
1. Look for these error types in the hardware error log, and then follow 
the procedures given in the maintenance documentation that is 
appropriate for the error type that was found.
Table 285: Test #314 DS1 CO Dial Tone Seizure Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 4