Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
838 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Error Log Entries and Test to Clear Values
Table 286: CO Trunk Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0 (
)
0
Any
Any
Any
test port location sh r 1
1 (
)
57347
None
15 (
any
Port Audit Update  (#36)
18
0
busyout trunk
WRN
OFF
release trunk grp#/mem#
130 (
)
None
WRN
ON
test port location sh r 2
257 (
)
50176
None
513 (
)
57364
None
MAJ 
MIN 
WRN
1
ON
769 (
)
57392
None
MAJ 
MIN  
WRN
OFF
1025 (
Any
Demand Diagnostic (#3)
MAJ 
MIN  
WRN
OFF
test port location sh r 2
1281 (
Any
Demand Diagnostic (#3)
MAJ 
MIN  
WRN
ON
test port location sh r 3
1537
Dial Tone Test (#0)
MAJ 
MIN  
WRN
OFF
test port location l r 2
The next two tests abort on the G700/G350 with Error Code 1412.
1793
Looparound and Conference Test 
(#33)
MAJ 
MIN  
WRN
ON
test port location l r 3
2049
NPE Cross Talk Test (#6)
MAJ 
MIN   
WRN
ON
test port location l r 3
2561 (
)
57345
None
2817 (
)
57360
None
2817 (
)
57393
None
2817 (
)
57484
Dial Tone Test (#0)
MAJ 
MIN  
WRN
OFF
test port location l r 1
 1 of 2