CO-TRK (Analog CO Trunk)
Issue 1 June 2005
841
 
513
57364
Ground detector stuck active.  After several occurrences, an on-board minor 
alarm is generated.  Run the short test sequence.  If test aborts with Error 
Code 1000, disconnect Tip and Ring and repeat short test.  If test still aborts, 
replace circuit pack.  If test passes, refer problem to CO.  If any other error 
code is received, pursue that problem.
769
57392
CO not releasing after call is dropped from PBX end, or the loop is not open 
after a disconnect.  After several occurrences, an off-board or on-board  
warning alarm is generated.  Refer problem to CO.
2561
57345
Single polarity ringing current.  This error results from abnormal ringing 
current, but does not prevent the incoming call from being accepted.  One 
cause could be that the reverse current detector associated with the port is 
failing.  (Will not be detected by any tests.) Another cause could be that 
normal current is not detected.  In this case, neither incoming nor outgoing 
calls can be completed, and the dial tone test will also fail.  The last cause 
could be that certain types of noise are present on the CO line during the 
silent period of ringing.  First check for other errors.  If the count for this error 
is very high (255), and every test passes, then either the reverse current 
detector is defective or the CO line is noisy.  If the CO line is suspect, make 
Tip and Ring observations.  If the line is determined to be noisy, refer the 
problem to the CO.  If the reverse current detector is defective, ignore this 
error.
2817
57360
Ground but no ringing.  This error occurs on an incoming call on a 
ground-start trunk.  If ringing is not detected within 5 seconds of the Tip being 
grounded, the call is still accepted.  If the CO is of the No.  5ESS.  switch 
type, ringing delays of more than 5 seconds during heavy traffic are fairly 
common.  Check for other errors.
2817
57393
The loop is opening too slowly after a disconnect.  This error indicates an 
on-board problem, although the trunk may be functional.  Check for other 
errors.
3073
57376
No loop current on incoming call.  The incoming destination has already 
answered and no loop current has been detected.  If this is a hard fault, the 
dial tone test and every outgoing call should also fail.  Check for other errors.
Table 287: CO Trunk Errors with No Tests  (continued)
Error 
Type
Aux 
Data
Error Description and Repair Action