Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
846 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
CO Demand Diagnostic Test (#3)
For ground start trunks, circuit pack or media module port relays are operated and checks are 
made to see if the port can detect and apply ground on the Tip lead.  This test also verifies that 
there is no external ground on the Ring lead.  In the absence of other failures, the circuit pack or 
media module should be replaced only if this test fails with the CO line disconnected.
This test also checks the on-board programmable transmission circuits that allow the circuit 
pack or media module to support transmission characteristics of several different countries.
PASS
Trunk was seized, and dial tone was detected.  User-reported troubles on 
this port should be investigated by using other port tests and by examining 
trunk or external wiring.
0
NO
BOARD
The test could not relate the internal ID to the port.
1. Verify that the board’s translations are correct.  Translate the board, if 
necessary.
2. Enter busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location
 This should re-establish the linkage between the internal ID and the port.
Table 288: Test #0 Dial Tone Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 4 of 4
Table 289: Test #3 CO Demand Diagnostic Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Could not allocate system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 4