CO-TRK (Analog CO Trunk)
Issue 1 June 2005
849
 
NPE Crosstalk Test (#6)
Note:
Note:
S8300
 / 
G700
: This test aborts with Error Code 1412.
The NPE Crosstalk test verifies that this port’s NPE channel talks on the selected time slot and 
never crosses over to time slots reserved for other connections.  If the NPE is not working 
correctly, one way and noisy connections may be observed.  This test is usually only part of a 
port’s long test sequence and executes in approximately 20 to 30 seconds.
0
NO
BOARD
The test could not relate the internal ID to the port (no board).
1. Verify that the board’s translations are correct.  Translate the board, if 
necessary.
2. Enter busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location  
This should re-establish the linkage between the internal ID and the port.
Table 289: Test #3 CO Demand Diagnostic Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 4 of 4
Table 290: Test #6 NPE Crosstalk Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 3