Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
852 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Looparound and Conference Circuit Test (#33)
Note:
Note:
S8300
 / 
G700
: This test aborts with Error Code 1412.
This test checks the reflective loop-around and conference capabilities of a CO port circuit.  The 
test uses 404-Hz, 1004-Hz, and 2804-Hz tones.  Each tone is transmitted separately through 
the loop and checked.
Table 291: Test #33 Looparound and Conference Circuit Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
7
ABRT
Conference Circuit test aborted.
1. Retry the command at 1-minute intervals up to 5 times.
129
ABRT
The 404-Hz reflective loop-around test aborted.  Response to the test 
request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
131
The 1004-Hz reflective loop-around test aborted.  Response to the test 
request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
133
The 2804-Hz reflective loop-around test aborted.  Response to the test 
request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available.  The port may 
be busy with a valid call.
1. Use display port location to determine the trunk group/
member number of the port.  Use status trunk to determine the 
service state of the port.  If the port is active, wait until it is idle before 
testing.
2. If the port status is active but the port is idle (no calls), check the error 
log for error type 769 (see the error log table for a description of this 
error and required actions).  The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals up to 
5 times.
 1 of 4