Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
854 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
7
FAIL
The conference capabilities of the port failed (Error Code 7).
129
The reflective 404-Hz Tone test failed.  No transmission was detected to or 
from the port (Error Code 129).
FAULT ISOLATION: Proceed as follows unless power or tone problems are 
suspected (see Description/Recommendation for Error Code 7 below).
2. To make sure the problem is on-board, disconnect the port from the 
CO and retry the test.  Coordinate this with the CO, or do it after busy 
hours; otherwise, the CO may put the connection out of service.
3. If the retry fails, replace the circuit pack.
4. If the retry passes and no troubles have been reported, disable the 
test.  If the retry passes and troubles have been reported, refer the 
problem to the CO.
131
The reflective 1004-Hz Tone test failed.  No transmission was detected to 
or from the port (Error Code 131).
FAULT ISOLATION: Proceed as follows unless power or tone problems are 
suspected (see Description/Recommendation for Error Code 7 below).
5. To make sure the problem is on-board, disconnect the port from the 
CO and retry the test.  Coordinate this with the CO, or do it after busy 
hours; otherwise, the CO may put the connection out of service.
6. If the retry fails, replace the circuit pack.
7. If the retry passes and no troubles have been reported, disable the 
test.  If the retry passes and troubles have been reported, refer the 
problem to the CO.
133
The reflective 2804-Hz Tone test failed.  No transmission was detected to 
or from the port (Error Code 133).
FAULT ISOLATION: Proceed as follows unless power or tone problems are 
suspected (see Description/Recommendation for Error Code 7 below).
8. To make sure the problem is on-board, disconnect the port from the 
CO and retry the test.  Coordinate this with the CO, or do it after busy 
hours; otherwise, the CO may put the connection out of service.
9. If the retry fails, replace the circuit pack.
10. If the retry passes and no troubles have been reported, disable the 
test.  If the retry passes and troubles have been reported, refer the 
problem to the CO.
Table 291: Test #33 Looparound and Conference Circuit Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 4