Avaya 03-300430 User Manual

Page of 2574
CO-TRK (Analog CO Trunk)
Issue 1 June 2005
855
 

129
131
133
FAIL
If the Looparound and Conference Circuit test (#33) fails for every port on a 
circuit pack, a -5 Volt power problem is indicated.  To investigate problems 
with a power unit, see 
If a red LED is lit on the power unit circuit pack, replace the pack.  
If the test fails on more than 1 port, check for errors on the TONE-BD or the 
TONE-PT.  If errors, take appropriate actions.  When the tone errors are 
cleared, rerun the test.  
S8700 MC
: if the test fails again, see 
PASS
CO Trunk Looparound and Conference test is successful.  User-reported 
troubles on this port should be investigated by using other port tests and by 
examining trunk or external wiring.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board).
1. Verify that the board’s translations are correct.  Translate the board, if 
necessary.
2. Enter busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location
This should re-establish the linkage between the internal ID and the port.
Table 291: Test #33 Looparound and Conference Circuit Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 4 of 4