Avaya 03-300430 User Manual

Page of 2574
CO-TRK (Analog CO Trunk)
Issue 1 June 2005
859
 
1905
ABRT
Intercept tone detected from far end.
1. Get the test line data from and verify it with the far end.
2. Dial the test number manually to see if the TTL is reached.
If not, then either the number is wrong or the far end is administered 
incorrectly.
1906
ABRT
Reorder tone detected from far end.
1. See actions for error code 1905.
1907
ABRT
Other unexpected tone detected from far end.
1. See actions for error code 1905.
1913
ABRT
Audible Ring detected from far end.
1. See actions for error code 1905.
1914
ABRT
Unidentified interrupted tone detected from far end.
1. See actions for error code 1905
1915
ABRT
Busy tone detected from far end.
1. Since the test line at the far end was busy, try the test again.
2. If the test continues to abort, the problem is with the far-end system.
1918
ABRT
Test progress tone not removed from far end (type 105 test line only).
1. The problem is with the far-end system; a technician at the far end 
should test the test line TN771 or ADFTC).
1919
ABRT
Unexpected far-end release
1. The problem is with the far-end system; a technician at the far end 
should test the test line (TN771 or ADFTC).
1920
ABRT
No response from far end.
1. The problem is with the far-end system; a technician at the far end 
should test the test line: TN771 or ADFTC.
1921
ABRT
No data returned from far end.
1. The problem is with the far-end system; a technician at the far end 
should test the test line: TN771 or ADFTC.
Table 293: Test #844-848 Transmission Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 4