Avaya 03-300430 User Manual
Communication Manager Maintenance-Object Repair Procedures
864 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
If the Error Type is greater than 1000, subtract 1000 from the Error Type field before
consulting the table.
consulting the table.
S8700 MC
:Before proceeding, if multiple CONFIG errors are simultaneously logged with an
Aux Data of 1, investigate any EXP-INTF (Expansion Interface) errors.
Once the port’s circuit-pack location has been determined from
on page 864, use list configuration all to determine
whether the circuit pack is inserted. If the circuit pack has already been inserted but the
error persists, replace the circuit pack. If not, insert the pack.
error persists, replace the circuit pack. If not, insert the pack.
Table 295: Converting Error Types To Carrier Locations
Error Type
Carrier Location
1
(
)
2
E01
3
E02
4
E03
5
E04
6
E05
7
E06
8
E07
9
E08
10
E09
11
E10
12
E11
13
E12
14
E13
15
E14
16
E15
17
E16
18
E17
19
E18
20
E19
21
E20
1 of 5