DAT-LINE (Data Line Port)
Issue 1 June 2005
873
 
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of-service due 
to TDM-BUS errors.
1. Resolve any TDM-BUS errors.
2. If the system is not handling heavy traffic, retry the command at 
1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system 
may be oversized for the number of tone detectors present, or some tone 
detectors may be out-of-service.
1. Resolve any TTR-LEV and TONE-PT errors.
2. If neither condition exists, retry the command at 1-minute intervals up 
to 5 times.
1004
ABRT
The port was in use on a valid call.
1. Determine whether the port is available for testing (status 
data-module).
2. When available, retry the command at 1-minute intervals up to 5 
times.
1020
ABRT
An existing Error Type 769 on this port prevented the test from running.
1. Follow the procedures for Error Type 769.
2000
ABRT
Response to the test command was not received within the allowable time 
period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Any
FAIL
The NPE of the tested port was transmitting in error, which can cause 
noisy and unreliable connections.
1. Replace the circuit pack.
PASS
The port is correctly using its allocated time slots. 
1. Investigate user-reported troubles on this port using other port tests 
and examining the ADU, external wiring, and customer equipment.
Table 297: Test #6 NPE Crosstalk Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2