DAT-LINE (Data Line Port)
Issue 1 June 2005
877
 
1042
ABRT
Port under test is a TTI port and has only default translations with no 
assigned extension. The executed test requires an assigned extension 
associated with the port being tested. Therefore, this test cannot 
successfully execute.
1. If there is a need to execute the test on this particular port, then the 
tester must ensure that the port is fully translated such that the port has 
an assigned extension.
1180
ABRT
There is no Maintenance/Test circuit pack digital port available to carry out 
the test.
1. Check to see if the Maintenance/Test digital ports are present. (Enter 
list config; ports 02 and 03 should show).
2. If the digital ports (02 and 03) on the Maintenance/ Test circuit pack are 
not present, see 
3. If the digital ports are present, retry the command at 1-minute intervals 
up to 5 times.
1181
ABRT
No time-slots available to connect digital ports for the test.
1182
ABRT
Internal system error. Failed to connect the digital ports with time-slots.
1. Retry the command at 1-minute intervals up to 5 times.
1340
ABRT
No Maintenance/Test digital port is currently available to perform this test.
1. Use list config to determine whether any Maintenance/Test digital 
ports (ports 02 and 03 on the Maintenance/Test circuit pack) are 
present in the system. At least one Maintenance/Test circuit pack must 
be present in PN 1 of the system. There should be at least two such 
ports present. If the ports are present, proceed to step 2. Otherwise, 
determine why no ports appear in the list config display. Refer to 
“M/T-DIG” and “M/T-BD”.
2. Look for M/T-DIG errors in the Error Log. If present, see 
3. If the ports are present and no errors are logged against them, retry the 
command at 1-minute intervals up to 5 times.
4. If the test continues to abort, replace the Maintenance/Test circuit pack.
Table 300: Test #171 Digital Loop-Around Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 4