Avaya 03-300430 User Manual

Page of 2574
DAT-LINE (Data Line Port)
Issue 1 June 2005
879
 
2313
ABRT
Failed to receive a response from the Maintenance/Test digital port.
1. Resolve any M/T-DIG errors.
2. Retry the command at 1-minute intervals up to 5 times.
3. If the test continues to abort, replace the Maintenance/Test circuit pack.
2314
ABRT
Data line port did not respond to downlinked message.
1. Busyout the digital port being tested on the data line circuit pack. Retry 
the command at 1-minute intervals up to 5 times.
2. If the test still aborts, replace the circuit pack.
2500
ABRT
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
 2000
FAIL
The test failed waiting for the transmitted data to be looped back.
1. Look for DATA-CHL errors in the Error Log. If present, refer to 
DATA-BD (Data Channel Processor circuit pack) Maintenance 
documentation.
2. Repeat this test.
3. If the test fails again, replace the Data Line circuit pack.
FAIL
The test failed because the data received did not match the data sent. This 
would indicate that there is a fault somewhere in the transmit/receive path 
to the TDM Bus, which will probably result in data corruption over this port. 
This test may fail if the Maintenance/Test digital port used by the test is not 
functioning properly.
1. Resolve any M/T-DIG errors.
2. Repeat Test #171.
3. If the test fails again, replace the data line circuit pack.
PASS
The port can correctly transmit/receive data. Investigate user-reported 
troubles on this port using other port tests and examining the ADU, external 
wiring, and customer equipment.
Table 300: Test #171 Digital Loop-Around Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 4 of 4