Notes:
a. Error Type 0
Run the short test sequence first. If every test passes, run the long test 
sequence. Refer to each test’s description, and follow its recommended procedures.
b. Error Type 1: DS1 Interface circuit pack or media module detects a hardware error on the 
DS1 DID trunk. The Aux Data field indicates the following:
Maintenance does not start any testing or generate any alarms in response to these errors.
c. Error Type 15 is a software audit error that does not indicate hardware malfunction. Run 
short test sequence, and investigate any errors.
d. Error Type 18: The trunk has been taken out of service by a demand busyout. No calls can 
be made on this trunk.
e. Error Type 130 indicates that the circuit pack or media module has been removed or has 
been insane for more than 11 minutes. To clear the error, reinsert or replace the circuit pack 
or media module.
f. Error Type 257: DS1 Interface circuit pack or media module detects a hardware error on 
the DS1 DID trunk. The Aux Data field indicate the source of the error:
g. Error Type 513: DS1 Interface circuit pack or media module detects a hardware error on 
the DS1 DID trunk. Aux Data 57392 indicates no external release on PBX disconnect.
h. Error Type 769: DS1 Interface circuit pack or media module detects a hardware error on 
the DS1 DID trunk. Aux Data 57393 indicates belated external release on PBX disconnect.
i. Error Type 1793: DS1 Interface circuit pack or media module is out-of-service. Look in the 
Hardware Error Log:
57476
On-hook before wink
57477
On-hook before ready to receive digits
57485
Wink too short for valid signal
57474
Rotary dial rate above 12 pulses per 
second
57473
Rotary dial rate below 8 pulses per 
second
If port is on
Look in
TN767 DS1 Board
DS1-BD
TN464 UDS1 Board
UDS1-BD
S8300
 / 
G700
: MM710 DS1 Media Module
MG-DS1