DID-DS1 (Direct Inward Dial Trunk)
Issue 1 June 2005
895
 
Any
FAIL
The NPE of the tested port did not conference the tones correctly. This 
can cause noisy and unreliable connections.
1. Enter list configuration board location. The circuit pack 
must be a TN767C V3 or later. The error log may have Error Type 
#1281.
2. Test every administered trunk on the board. If one fails, this could be 
an off-board problem (such as an incoming seizure or an off-hook port 
seizure during the test). Retest the board.
3. If every port fails, a -5V power problem is indicated. Check 
4. If several ports fail, resolve any 
rerun the test.
5. If the retry passes and troubles are reported, coordinate isolation with 
the CO. Make sure that the switch, the CO, and any NTCE equipment 
(the CSUs) have the correct administration.
6. Replace the circuit pack.
PASS
The port can correctly conference multiple connections. Investigate 
user-reported troubles on this port using other port tests and by examining 
station, trunk, or external wiring.
This test always passes for TN742 Analog circuit packs prior to Vintage 4.
0
NO 
BOARD
The test could not relate the internal ID to the port. This could be due to 
incorrect translations, no board is inserted, an incorrect board is inserted, 
or an insane board is inserted.
1. Verify that the board’s translations are correct. Use lIst config
and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, enter 
busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the link between the internal ID and the port. 
If not, check to see that there is a valid board inserted.
Table 305: Test #7 Conference Circuit Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation