DID-DS1 (Direct Inward Dial Trunk)
Issue 1 June 2005
897
 
PASS
Trunk translation has been updated successfully. The current trunk states 
kept in the DS1 Interface circuit pack media module and switch software 
are consistent. If the trunk is busied out, the test will not run but will return 
PASS. To verify that the trunk is in-service:
1. Enter status trunk to verify that the trunk is in-service. If the trunk 
is in-service, no further action is necessary. If the trunk is 
out-of-service.
2. Enter release trunk to put the trunk back into in-service.
3. Retry the test command.
0
NO 
BOARD
The test could not relate the internal ID to the port (no board). This could 
be due to incorrect translations, no board is inserted, an incorrect board is 
inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Use the list config 
command, and resolve any problems that are found.
2. If the board was found to be correctly inserted in step 1, enter 
busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location long
This should re-establish the linkage between the internal ID and the 
port. If this is not the case, check to see that there is a valid board 
inserted.
Table 306: Test #36 Port Audit and Update Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2