Communication Manager Maintenance-Object Repair Procedures
898 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
DID-TRK (Direct Inward Dial Trunk)
S8700 | 8710
 / 
S8500
 / 
S8300
Note:
Note:
Many trunk problems are caused by incorrect settings of parameters on the trunk 
group administration screen. Settings must be compatible with the local 
environment and with parameter settings on the far end. Refer to Administrator 
Guide for Avaya Communication Manager, 03-300509
, for
 information about how 
to administer trunks. The Application Notes section of that book shows the 
correct settings for administrable timers and other parameters on a 
country-by-country basis.
Direct Inward Dial (DID) trunks coming from the Central Office (CO) allow outside parties to call 
directly to an extension in the system. DID Trunk circuit packs include:
DID trunk circuit packs and the MM711 Media Module support eight incoming-only ports. Each 
port provides an interface between the 2-wire analog CO line and the 4-wire TDM bus on the 
switch.
S8300
 / 
G700
 Although the DID-TRK MO is provided for a G700/G350 Media Gateway, this MO 
only partially supports the MM711 Analog Media Module.
MO Name in 
Alarm Log
Alarm
Level
Initial SAT Command to Run
Full Name of MO
DID-TRK
MAJ
1
1. A MAJOR alarm on a trunk indicates that alarms on these trunks are not downgraded by 
set options and that at least 75 percent of the trunks in this trunk group are alarmed.
test port location l
DID Trunk
DID-TRK
MIN
test port location l
DID Trunk
DID-TRK
WRN
None
DID Trunk
TN753 United 
States
TN2146
Belgium and the 
Netherlands
TN2139
Italy
TN 436
Australia
TN459 United 
Kingdom