Avaya 03-300430 User Manual

Page of 2574
DID-TRK (Direct Inward Dial Trunk)
Issue 1 June 2005
903
 
NPE Crosstalk Test (#6)
Note:
Note:
S8300
 / 
G700
T
his test aborts with Error Code 1412.
The NPE Crosstalk test verifies that this port’s NPE channel talks on the selected time slot on 
the TDM bus and never crosses over to time slots reserved for other connections. If the NPE is 
not working correctly, 1-way and noisy connections may be observed. This test is usually only 
part of a port’s long test sequence and executes in about 20 to 30 seconds.
Looparound and Conference Circuit test (#33)
S8300
 / 
G700
This test aborts with Error Code 1412.
X
ND
Port Audit Update test (#36)
X
X
ND
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test 
Sequence
Long Test 
Sequence
D/ND
1
 2 of 2
Table 308: Test #6 NPE Crosstalk Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Could not allocate the necessary system resources for this test. This could 
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABRT
System resources required to run this test are not available. The port may 
be busy with a valid call.
1. Enter display port location to determine the station extension, 
attendant number, or trunk group/member number of the port. Enter 
status stationstatus attendant, or status trunk to 
determine the service state of the port. If the port is in use, wait until it 
is idle before testing. Attendants are always in use (off-hook) if the 
handset is plugged in and the port is not busied out.
2. If the port status is active but the port is idle (no calls), check the Error 
Log for Error Type 513. The port may be locked up.
3. If the port status is idle, retry the command at 1-minute intervals up to 5 
times.
 1 of 3