ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out-of- service due 
to TDM-BUS errors.
1. If the system has no TDM-BUS errors and is not handling heavy traffic, 
retry the command at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present, or some Tone 
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up 
to 5 times.
1004
ABRT
The port was seized by a valid call during the test.
1. Enter display port location to determine the station extension, 
attendant number, or trunk group/member number of the port. Enter 
status stationstatus attendant, or status trunk to 
determine the service state of the port. If the port is in use, wait until it 
is idle before testing. Attendants are always in use (off-hook) if the 
handset is plugged in and the port is not busied out.
2. Retry the command at 1-minute intervals up to 5 times.
S8300
 
G700
1412
ABRT
This test does not execute on a G700 media gateway.
2000
ABRT
Response to the test was not received within the allowable time period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources for this test. This could 
be due to a failure to seize the port.
1. Retry the command at 1-minute intervals up to 5 times.
Table 308: Test #6 NPE Crosstalk Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3