Avaya 03-300430 User Manual

Page of 2574
DID-TRK (Direct Inward Dial Trunk)
Issue 1 June 2005
913
 
Port Audit Update Test (#36)
This test sends updates of the DID port translation for every port on the circuit pack or media 
module that has been translated. The update is non-disruptive and guards against possible 
corruption of translation data contained on the circuit pack or media module. No response 
message is expected from the circuit pack or media module once it receives translation 
updates. The port translation data includes:
Wink or immediate start trunk
Dial tone or rotary dialing trunk
Rotary dialing inter-digit timing
Network balance R/RC
Disconnect timing
0
NO 
BOARD
The test could not relate the internal ID to the port (no board).
1. Verify that the board’s translations are correct. Translate the board if 
necessary.
2. Enter busyout board location
3. Enter reset board location
4. Enter release board location
5. Enter test board location
This should re-establish the linkage between the internal ID and the 
port.
Table 310: Test #35 Port Diagnostic Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 3 of 3
Table 311: Test #36 Port Audit Update Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
 1 of 2