Notes:
a. Error Type 0
:
Run the short test sequence first. If every test passes, run the long test
sequence.
b. Error Type 1; Aux Data - 40987 could indicate a noisy port or link. This is an off-board
problem detected by the port circuit. Check for defective wiring, a defective voice terminal,
or move voice terminal closer to the switch (in terms of feet of wire from the jack to the
switch). If the problem still exists, replace the circuit pack. Once the problem is resolved, the
alarm is retired after a predetermined amount of time.
or move voice terminal closer to the switch (in terms of feet of wire from the jack to the
switch). If the problem still exists, replace the circuit pack. Once the problem is resolved, the
alarm is retired after a predetermined amount of time.
c. Error Type 1; Aux Data - 1 to 20 occurs when at least 15 off-board problems with the link
to the terminal have been detected. When an error with the link is detected, an on-board
counter is incremented.
counter is incremented.
The user could experience a noisy port or link. This is an off-board problem detected by the
port circuit. Check for defective wiring, a defective voice terminal, or move voice terminal
closer to the switch (in terms of feet of wire from the jack to the switch). If the problem still
exists, replace the circuit pack. Once the problem is resolved, the alarm is retired after a
predetermined amount of time.
port circuit. Check for defective wiring, a defective voice terminal, or move voice terminal
closer to the switch (in terms of feet of wire from the jack to the switch). If the problem still
exists, replace the circuit pack. Once the problem is resolved, the alarm is retired after a
predetermined amount of time.
d. Error Type 18 is logged when the port in question is busied out by maintenance personnel.
Use release port location to release the port from busyout.
1793
Voice and Ctrl.
Local Loop test
(#13)
MIN
WRN
1
ON
test port location l r 3
2049
NPE Crosstalk
test (#9)
MIN
WRN
2
ON
test port location l r 3
2304 (
None
2305 (
32770
40969
None
2817 (
Any
None
OFF
3585 (
3840 (
40965
40989
None
3841 (
41029
None
1. Major alarms may be downgraded to Warning alarms based on the value used in set options.
Table 319: Digital Line Error Log Entries (continued)
Error
Type
Type
Aux
Data
Data
Associated Test
Alarm
Level
Level
On/Off
Board
Board
Test to Clear Value
2 of 2