Avaya 03-300430 User Manual

Page of 2574
DIG-LINE (Digital Line)
Issue 1 June 2005
935
 
m. Error Type 2305; Aux Data - 32770: This indicates that the station went off-hook while it 
was in the ready-for-service state. Use status station to determine the state of the 
station. The off-hook should have moved the station to ready-for-service. No craft action is 
necessary.
n. Error Type 2305; Aux Data - 40967: An in-line maintenance error has generated an 
off-board warning due to some problem with the link to the voice terminal. This can be 
ignored if no user complaints are received. Otherwise, make sure the voice terminal is 
connected, check for defective wiring, check for a defective voice terminal, and move voice 
terminal to a jack that is closer to the switch (in terms of feet of wiring between the jack and 
the switch). If the problem still exists, replace the circuit pack or media module. Once the 
problem has been resolved, the alarm will be retired after a predetermined amount of time.
o. Error Type 2817: Port Level Hyperactivity. Fifty or more CCMS uplink messages were 
received from the port within ten seconds. The user is taken out of service for a short 
interval of time (default 30 seconds).
p. Error Type 3585: This error type indicates that an attempt to execute a firmware download 
of a DCP terminal has failed. The DCP terminal must be replaced before the firmware 
download can be executed successfully. Replace the DCP terminal and re-execute the 
firmware download.
q. Error Type 3840; Aux Data - 40965:
 
No terminal is connected to the Digital Line board. No 
maintenance action is required.
r. Error Type 3840; Aux Data - 40989: An uplink message has been logged indicating that 
the Electric Power Feed (EPF) is on with no load on it. No action is necessary.
s. Error Type 3841: The circuit pack’s or media module’s message buffer is full. This may be 
caused by having many display phones with heavy traffic connected to the circuit pack or 
media module. No action is necessary.