Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
938 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
1004
ABRT
The port was seized by a valid call during the test.
1. Enter display port location to determine the station extension 
or attendant number of the port. Use status station or status 
attendant
 to determine the service state of the port. If the port is in 
use, wait until it is idle before resetting. Attendants are always in use 
(off-hook) if the handset is plugged in and the port is not busied out.
2. Retry the command at 1-minute intervals up to 5 times.
1005
ABRT
The installed circuit pack does not support this operation.
S8300
 /
G700
1412
ABRT
This test does not execute on a G700 media gateway.
2000
ABRT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
System resources required to run this test are not available.
1. Make sure terminal is connected and repeat test.
2. If test fails replace terminal and repeat test.
3. Retry the command at 1-minute intervals up to 5 times.
14
FAIL
The primary channel is not operating properly. User impact may range 
from noticing nothing to not being able to use the port.
1. Check the results of “Voice and Control Channel Local Loop test 
(#13).
2. If that test fails, suspect the Digital Line circuit pack. If that test passes 
then replace the terminal.
3. If both tests fail, and component replacement does not change the 
results, then:
a. Run circuit pack tests to check the tone generator circuit and the 
Tone Detector circuit using test board location.
b. Resolve any problems that are detected on the Tone Generator 
circuit or Tone Detector circuit.
1015
ABRT
The station is not busied out (busyout station).
Table 320: Test #1201 Digital Terminal Remote Loop-around Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3