DIG-LINE (Digital Line)
Issue 1 June 2005
941
 
1003
ABRT
The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present, or some Tone 
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up 
to 5 times.
1004
ABRT
The port was seized by a valid call during the test. The test has been 
aborted.
1. Enter display port location to determine the station extension 
or attendant number of the port. Use status station or status 
attendant
 to determine the service state of the port. If the port is in 
use, wait until it is idle before testing. Attendants are always in use 
(off-hook) if the handset is plugged in and the port is not busied out.
1020
ABRT
Test disabled by background testing. Use status station to determine 
when station is available for testing.
S8300
 /
G700
1412
ABRT
This test does not execute on a G700 media gateway.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Retry the command at 1-minute intervals up to 5 times.
2
FAIL
The Network Processing Element (NPE) of the tested port was transmitting 
in error.
Error code 1 = Crosstalk test failed on the primary channel.
Error code 2 = Crosstalk test failed on the secondary channel.
1. Replace circuit pack.
PASS
The port is correctly using its allocated time slots.
1. To verify that this is not an intermittent problem, repeat this test up to 
10 times.
2. If complaints persist, examine the station, connections, and wiring.
Table 321: Test #9 Digital Line NPE Crosstalk Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2