Avaya 03-300430 User Manual

Page of 2574
DIG-LINE (Digital Line)
Issue 1 June 2005
943
 
1000
ABRT
System resources required to run this test are not available. The port may 
be busy with a valid call.
1. Enter display port location to determine the station extension 
or attendant number of the port. Use status station or status 
attendan
t to determine the service state of the port. If the port is in 
use, wait until it is idle before testing. Attendants are always in use 
(off-hook) if the handset is plugged in and the port is not busied out.
2. If the port status is idle, then retry the command at 1-minute intervals 
up to 5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Electronic Power Feed test passed. The message to turn on the power to 
the station was successfully sent to the port.
1. Although, except for the previous Internal system error, this test never 
actually returns a FAIL result, it will log an error indicating the real 
results of the test. Check the Error Log for any entries with Error Types 
767 or 769 after the test completes.
2. If Error Type 767 appears in the Error Log, this indicates that the test 
sensed no problems with the power to the station. To verify that the 
station is powered up correctly, run a self-test on the station and check 
that every feature button is operating.
3. If Error Type 769 appears in the Error Log, this indicates some 
problem with the power to the station. Check for a short in the wiring, a 
damaged jack, a defective voice terminal, or an incorrect type of 
terminal.
Table 322: Test #11 Digital Line Electronic Power Feed Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2