Avaya 03-300430 User Manual

Page of 2574
DIG-LINE (Digital Line)
Issue 1 June 2005
945
 
1001
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1002
ABRT
The system could not allocate time slots for the test. The system may be 
under heavy traffic conditions or it may have time slots out of service due to 
TDM-BUS errors.
1. If system has no TDM-BUS errors and is not handling heavy traffic, 
repeat test at 1-minute intervals up to 5 times.
1003
ABRT
The system could not allocate a tone receiver for the test. The system may 
be oversized for the number of Tone Detectors present, or some Tone 
Detectors may be out of service.
1. Resolve any TTR-LEV errors.
2. Resolve any TONE-PT errors.
3. If neither condition exists, retry the command at 1-minute intervals up 
to 5 times.
1004
ABRT
The port was seized by a valid call during the test. The test has been 
aborted.
1. Use display port location to determine the station extension or 
attendant number of the port. Use status station or status 
attendant
 to determine the service state of the port. If the port is in 
use, wait until it is idle before testing. Attendants are always in use 
(off-hook) if the handset is plugged in and the port is not busied out.
2. Retry the command at 1-minute intervals up to 5 times.
S8300
 /
G700
 
1412
ABRT
This test does not execute on a G700 Media Gateway.
2000
ABRT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run this test.
1. Rerun the test at 1-minute intervals up to 5 times.
7
FAIL
Conference test failed on primary channel. In some cases, users may not 
notice disruption in service. In extreme cases, conferencing feature may not 
work at all.
Table 323: Test #13 Voice and Control Channel Local Loop Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3