Avaya 03-300430 User Manual

Page of 2574
DIOD-DS1 (DS1 DIOD Trunk)
Issue 1 June 2005
953
 
Three trunk service states are specified by DS1 DIOD trunk maintenance:
Error Log Entries and Test to Clear Values
out-of-service
The trunk is in a deactivated state and cannot be used for either 
incoming or outgoing calls.
in-service
The trunk is in an activated state and can be used for both incoming 
and outgoing calls.
disconnect
(ready-for-service)
The trunk is in an activated state but can only be used for an 
incoming call.
Table 326: DS1 DIOD Trunk Error Log Entries 
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
0 (
)
0
Any
Any
Any
test trunk grp#/mem#
1(
57408
1(
57487
57476
57477
57485
Any
Port Audit and 
Update (#36)
)
0
busyout 
trunk grp#/
mem#
WRN
OFF
release trunk grp#/mem#
None
WRN
ON
test trunk grp#/mem#
57392
DS1 CO Dial 
Tone Seizure 
(#314)
MAJ
MIN
1
OFF
57393
DS1 CO Dial 
Tone Seizure 
(#314)
MAJ
MIN
OFF
57484
1025 (
51200
 1 of 2