Avaya 03-300430 User Manual
DIOD-DS1 (DS1 DIOD Trunk)
Issue 1 June 2005
959
1000
ABRT
System resources required to run this test are not available. The port may
be in use on a valid call.
be in use on a valid call.
1. Use status station or status trunk to determine when the port
is available for testing.
1004
ABRT
The port has been seized by a user for a valid call.
1. Use status station or status trunk to determine when the port
is available for testing.
2. Retry the command at 1-minute intervals up to 5 times.
1018
ABRT
Test disabled by administration. This only applies to analog stations.
1. To enable test, use change station extension and set the Test
field to y. Run the test.
1020
ABRT
The test did not run due to a previously existing error on the specific port or
a more general circuit pack error.
a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit
pack and attempt to diagnose the previously existing error.
2000
ABRT
Response to the test request was not received within the allowable time
period.
period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2053
ABRT
At least one of the following errors is found on the DS1 circuit pack:
●
1281 – Loss of signal
●
1793 – Blue alarm
●
2049 – Red alarm
●
2305 – Yellow alarm
●
1537 – Hyperactivity
Look for the previous error types in the Hardware Error Log, and follow the
or
on page 2374 maintenance
documentation for the listed error types.
Table 329: Test #7 Conference Circuit Test (continued)
Error
Code
Code
Test
Result
Result
Description / Recommendation
2 of 3