Avaya 03-300430 User Manual

Page of 2574
DIOD-DS1 (DS1 DIOD Trunk)
Issue 1 June 2005
959
 
1000
ABRT
System resources required to run this test are not available. The port may 
be in use on a valid call.
1. Use status station or status trunk to determine when the port 
is available for testing.
1004
ABRT
The port has been seized by a user for a valid call.
1. Use status station or status trunk to determine when the port 
is available for testing.
2. Retry the command at 1-minute intervals up to 5 times.
1018
ABRT
Test disabled by administration. This only applies to analog stations.
1. To enable test, use change station extension and set the Test 
field to y. Run the test.
1020
ABRT
The test did not run due to a previously existing error on the specific port or 
a more general circuit pack error.
1. Examine Error Log for existing errors against this port or the circuit 
pack and attempt to diagnose the previously existing error.
2000
ABRT
Response to the test request was not received within the allowable time 
period.
1. Rerun the test at 1-minute intervals up to 5 times.
2100
ABRT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2053
ABRT
At least one of the following errors is found on the DS1 circuit pack:
1281 – Loss of signal
1793 – Blue alarm
2049 – Red alarm
2305 – Yellow alarm
1537 – Hyperactivity
Look for the previous error types in the Hardware Error Log, and follow the 
procedures given in the 
or 
documentation for the listed error types.
Table 329: Test #7 Conference Circuit Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 3