Avaya 03-300430 User Manual

Page of 2574
Server Alarms
96 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Alarm Log Entries
Notes:
1. Event ID #1 Handshake Test failed — With 3 consecutive failures of either the periodic or 
on-demand test, the following Minor alarm is logged:
#1,ACT,USB1,A,1,MIN,USB Modem handshake test failed
2. Event ID #2 Modem Off-Hook test failed — With 3 consecutive failures of this test, the 
following Major alarm is logged:
#1,ACT,USB1,A,2,MAJ,USB Modem Off-Hook test failed
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the following table. For example, by clearing 
error codes associated with the Handshake test, you may also clear errors generated by other 
tests in the testing sequence.
-t arg
Specific test to perform. 
Possible values for arg are: reset_usb | handshake | off-hook | 
-?
Usage (this).
Table 27: USB1 Alarm Log Entries
EVENT
ID#
Aux 
Data
Associated Test
Alarm 
Level
On/
Off 
Board
Linux Test to 
Clear Value
1 (
Handshake test 
MIN
ON
testdupboard
2 (
Modem Off-Hook test
MAJ
ON
testdupboard
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1. D = Destructive; ND = Nondestructive
Handshake test
X
X
D
Off-Hook test
X
X
D
Reset USB test
X
X
D