DIOD-TRK (DIOD Trunk)
Issue 1 June 2005
969
 
1005
ABRT
Trunk has been administered as incoming-only; or DID trunk group type; dial 
tone can only be obtained on outgoing trunks. This is a normal condition.
S8300
 
/
G700
1412
ABRT
This test does not execute on a G700 Media Gateway.
2000
ABRT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
Trunk was seized, but dial tone could not be detected.
1. Check for errors on TONE-BD or TONE-PT. Clear any errors and 
repeat test.
2. If error has still not cleared, refer problem to CO.
2002
FAIL
Seizure portion of test failed due to hardware problem. Fault is usually 
caused by a disconnected trunk.
1. Check trunk wiring to ensure good connection; repeat test if wiring 
correction made.
2. Locate another identical CO trunk and swap its wiring with one under 
test. Repeat test on both trunks and determine whether problem follows 
trunk or remains at original port. If problem follows trunk, refer problem 
to CO. If problem remains at port, replace the circuit pack and repeat 
test.
1009
PASS
Detected tone was not pure dial tone. No action required.
PASS
Trunk was seized, and dial tone was detected. User-reported troubles on this 
port should be investigated by using other port tests and by examining trunk 
or external wiring.
Table 333: Test #0 Dial Tone Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation