Avaya 03-300430 User Manual

Page of 2574
Communication Manager Maintenance-Object Repair Procedures
974 Maintenance Procedures for Avaya Communication Manager 3.0, Media Gateways and Servers
 
Port Audit Update Test (#36)
This test sends updates of the CO port translation for every translated port on the circuit pack or 
media module. The update is non-disruptive and guards against possible corruption of 
translation data contained on the circuit pack or media module. No response message is 
expected from the circuit pack or media module once it receives translation updates. The port 
translation data includes: ground or loop start trunk, tone or rotary dialing trunk, rotary dialing 
inter-digit timing, network balance R/RC, and disconnect timing.
Table 336: Test #36 Port Audit Update Test 
Error 
Code
Test 
Result
Description / Recommendation
ABRT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
2100
ABRT
Could not allocate the necessary system resources to run the test.
FAIL
Internal system error.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
This test passed. Translation information was successfully updated on the 
circuit pack or media module. User-reported troubles on this port should be 
investigated by using other port tests and by examining trunk or external 
wiring. If the trunk is busied out, the test does not run, but returns PASS. To 
verify that the trunk is in-service:
1. Enter status trunk to verify that the trunk is in-service. If the trunk is 
in-service, no further action is necessary. If the trunk is out-of-service, 
continue to step 2.
2. Enter release trunk to put trunk back into in-service.
3. Retry the test command.