DS1-BD (DS1 Interface Circuit Pack)
Issue 1 June 2005
983
 
Notes:
a. Error Type 0: Run the short test sequence first. If every test passes, run the long test 
sequence. Refer to the test’s description and follow the recommended procedures.
b. Error Type 1: the circuit pack stopped functioning or is not completely administered. The 
alarm is logged approximately 15 minutes after the circuit pack has been removed or 11 
minutes after the SAKI test (#53) fails.
To be completely administered, a DS1 circuit pack must:
Have an entry in the circuit plan field in change circuit-packs
Be administered using add ds1 location 
Be physically inserted in the correct slot
2306
Any
Yellow Alarm 
Inquiry test (#141)
MIN
OFF
test board location
2561
Any
Major Alarm 
Inquiry test (#142)
MIN 
WRN
OFF
test board location
2817
Minor Alarm 
Inquiry test (#143)
MIN 
WRN
OFF
test board location
3073 to
3160 (
)
Any
Slip Alarm Inquiry 
test (#144)
MIN 
WRN
OFF
test board location r 6
3329 to
3345 (
)
Any
Misframe Alarm 
Inquiry test (#145)
MIN 
WRN
OFF
test board location r 6
3840 (
Any
None
3900 (
)
Any
CPE Loopback 
Jack test (#1212)
3901(
)
Any
Far CSU 
Loopback test 
(#1213)
3902 (
)
Any
One-Way Span 
test (#1214)
3999 (
)
Any
None
Table 338: DS1 Interface Circuit Pack Maintenance Error Log Entries  (continued)
Error 
Type
Aux 
Data
Associated Test
Alarm 
Level
On/Off 
Board
Test to Clear Value
 4 of 4