Avaya 03-300430 User Manual

Page of 2574
DS1-BD (DS1 Interface Circuit Pack)
Issue 1 June 2005
991
 
0
NO 
BOARD
The test could not relate the internal ID to the port (no board).
This could be due to incorrect translations, no board is inserted, an 
incorrect board is inserted, or an insane board is inserted.
1. Verify that the board’s translations are correct. Use add ds1 
location to administer the DS1 interface if it is not already 
administered.
2. If board was already administered correctly, check the error log to 
determine whether the board is hyperactive. If so, the board was shut 
down. Reseating the board will re-initialize it.
3. If the board was found to be correctly inserted in step 1, enter 
busyout board.
4. Enter reset board
5. Enter release board
6. Enter test board long
This should re-establish the linkage between the internal ID and the 
port.
Table 341: Test #52 Control Channel Loop-around Test  (continued)
Error 
Code
Test 
Result
Description / Recommendation
 2 of 2