Intelligent Motion Systems Motion Detector User Manual

Page of 74
1-8
Microstepping MForce PowerDrive Manual Revision R032008
Mechanical Specifications - 
Dimensions in Inches (mm)
Figure 1.2.1: MForce PowerDrive Mechanical Specifications
Microstepping MForce PowerDrive Setup Parameters
Name
Function
Range
Units
Default
MHC
Motor Hold Current
0 to 100
percent
5
MRC
Motor Run Current
1 to 100
percent
25
MSEL
Microstep Resolution
1, 2, 4, 5, 8, 10, 16, 25, 32, 50, 
64, 100,108, 125, 127,128, 
180, 200, 250, 256
µsteps per 
full step
256
DIR
Motor Direction Override
0/1
CW
HCDT
Hold Current Delay Time
0 or 2-65535
mSec
500
CLK TYPE
Clock Type
Step/Dir. Quadrature, Up/Down 
(CW/CCW)
Step/Dir
CLK IOF
Clock and Direction Filter
50 nS to 12.9 µS 
(10 MHz to 38.8kHz)
nS (MHz)
200nS(2.5 
MHz)
USER ID
User ID
Customizable
1-3 characters
IMS
WARN TEMP
Warning Temperature
0 to +125
ºC
80
EN ACT
Enable Active High/Low
High or Low
High
PWM MSK
PWM Mask
0 to 255
102
PWM PER
PWM Duty Cycle
0 to 95
Percent
90%
PWM FREQ
PWM Frequency Range
0 to 255
170 (20kHz to 
60 kHz)
PWM CTL
PWM Control
See Section 2.4
See Section 2.4
0-10010
Table 1.2.6: Setup Parameters
Setup Parameters
The following table illustrates the setup parameters. These are easily configured using the IMS SPI Motor Interface 
configuration utility. An optional Parameter Setup Cable is available and recommended with the first order.
3.473
(88.21)
2X 0.580
(2X 14.73)
Ø 0.187 ±0.01
(Ø 4.75 ±0.25)
2X #8 Screws
for End Mount 
3.00 ±0.01
(76.2 ±0.25)
2.116
(53.75)
0.225
(5.72)
P4
P3
P1
3.473
(88.21)
Ø 0.160 ±0.01 Thru
(Ø 4.06 ±0.25 Thru)
4X #6 Screws
for Flat Mount
0.308 TYP.
(7.82 TYP.)
2.931 TYP.
(74.45 TYP.)
3.897
(98.98)
0.417 TYP.
(10.59 TYP.)
0.160 ±0.01
(4.06 ±0.25)
2.950