Part 2: Interfacing and Configuring
Shield to Earth Ground
on Supply End Only
Ferrite Beads
*L z 0.5 MH
* 0.5 MH is a typical starting point for the Common Mode Line Filters. By increasing  or decreasing 
   the value of L  you can set the drain current to a minimum to meet your application’s requirements.
Common Mode
Line Filters (2x)
From MicroLYNX
Shielded/Twisted Pair
Cable Length
as required
Motor
Connections
A
A
B
B
A
A
B
B
MForce
PowerDrive
Phase Outputs
Example B: Motor Cabling Greater Than 50 Feet
Figure 2.3.8: Motor Cableing Greater than 50 Feet
Recommended Motor Cable AWG Sizes
MForce PowerDrive Recommended Motor Cable AWG 
1 Amperes (Peak)
5 Amperes (Peak)
Length (Feet)
10
25
50*
75* 100*
Length (Feet)
10
25
50*
75*
100*
Minimum AWG
20
20
18
18
16
Minimum AWG
16
16
14
12
12
2 Amperes (Peak)
6 Amperes (Peak)
Length (Feet)
10
25
50*
75* 100*
Length (Feet)
10
25
50*
75*
100*
Minimum AWG
20
18
16
14
14
Minimum AWG
14
14
14
12
12
3 Amperes (Peak)
7 Amperes (Peak)
Length (Feet)
10
25
50*
75* 100*
Length (Feet)
10
25
50*
75*
100*
Minimum AWG
18
16
14
12
12
Minimum AWG
12
12
12
12
12
4 Amperes (Peak)
*Use the alternative methods illustrated in example 
B when cable length is ≥ 50 feet. Also, use the same 
current rating when the alternate AC power is used.
Length (Feet)
10
25
50*
75* 100*
Minimum AWG
18
16
14
12
12
Table 2.3.1: Recommended Wire Gauges