Bosch H-264 User Manual

Page of 15
 
 
Security Systems 
 
 
 
 
 From 
 
Telephone 
Nuremberg 
 STVC/PRM 
Product Management 
+49 911 93456 0 
24.01.2013 
 
 
 
 
 
 
 
11  
 
BOSCH and the symbol are registered trademarks of Robert Bosch GmbH, Germany 
Web browser interface 
•  Mobile device can access the devices via browsers and are forwarded to specific pages, 
optimized for viewing on mobile devices. These pages use HTML5 technology with HTTP 
streaming for the live stream and HTTP download of recording files in .mp4 format. 
Apple devices support live view and playback of recordings. 
Android and Windows Phone support live view only. 
•  Pixel Counter allows counting of pixels in respect to stream resolution, e.g. to check if number 
of pixels of object in view is sufficient for identification. 
•  I-Frame only stream can be configured to be shown on the LIVEPAGE. 
•  The expected frame rate for I-Frame only is indicated on recording page. 
•  Display of V-SDK overlay icons can be configured on the LIVEPAGE settings 
•  Preview images in settings pages can be expanded for more details, including 1:1 view. 
•  Buttons to reboot a camera remotely and to set all camera and encoder parameters to factory 
defaults have been added. 
 
ONVIF 
•  ONVIF Profile S is supported. 
 
Miscellaneous 
•  Debug logging has been enhanced to ease investigation during support cases. 
•  Holidays (Special Days) are updateable without stop/start recording. 
•  AAC is supported in addition to G.711 and L16 audio codecs and is selectable for recording.  
It provides higher audio quality than G.711 with 16 kHz sampling rate at significantly lower bit 
rate of approx. 48 kbps. 
•  Firmware files of all three platforms are combined into a common file that can be uploaded to 
any applicable product, regardless of the platform. 
 
Camera specific features 
•  Enhanced tone mapping for VOT cameras 
•  Lens installation aid for motorized lens devices 
 
5.7  Changes with FW 4.54.0026 
 
•  For wireless cameras, protocol for connection handling to access point has been improved: 
•  For VOT-320, no alarm was signalled when VCA was reconfigured. This has been fixed.