4.1.2
Priority microphone (input 1)
The priority microphone (or a generic call station) that 
can be used with push to talk (PTT) should be 
connected to “microphone/line 1 input with trigger”. 
The PTT mode can be activated by setting the DIP 
switch (2) at the rear of the unit. 
Microphone/line 1 input with trigger has priority over 
all other microphone/line inputs. If, however, the “Tel. 
emergency/70V input” receives a signal, all inputs 
including microphone/line 1 input with trigger will be 
overruled.
The microphone/line 1 input with trigger has a Euro 
style pluggable screw terminal connector. This Euro 
style pluggable screw terminal connector has a trigger 
input, which can be used in combination with the Euro  
connector.
The priority microphone can be connected to the 
microphone/line 1 input with trigger as follows:
Euro connector with trigger. See figure 4.2.
Euro connector only (without trigger).
 
Set the DIP switch settings for microphone/line 1 with 
trigger, as required. See section 4.3.
Note
When connecting an unbalanced line level 
(200 mV) signal to the microphone/line input, 
connect it as follows: Signal to pin 2, pin 1 and 
pin 3 to ground.
figure 4.2: Euro connector with trigger