Bosch nbn-932 User Manual

Page of 44
DinionHD 1080p HDR
Installation | en
23
Bosch Security Systems
Installation Manual
AM18-Q0614 | v1.0 | 2012.03
5.5
Alarm and relay connector
Figure 5.5
Alarm and relay connector pins
Max. wire diameter AWG 22-28 for both stranded and 
solid; cut back 5 mm (0.2 in) of insulation.
Alarm output relay switching capability: Max voltage 30VAC 
or +40 VDC. Max 0.5 A continuous, 10 VA.
Alarm in: TTL logic, +5V nominal, +40 VDC max, DC coupled 
with 22 kOhm pull-up to +3.3 V.
Alarm in: configurable as active low or active high.
Max. 42 V allowed between camera ground and each of the 
relay pins.
Use the alarm input to connect external alarm devices such as 
door contacts or sensors. A zero potential make-contact or 
switch can be used as the actuator (use a bounce-free contact 
system).
Use the alarm relay output for switching external devices such 
as lamps or sirens. 
Pin
Alarm socket
1
Alarm in 1
2
Alarm in 2
3
Relay out contact 1
4
Ground
5
Ground
6
Relay out contact 2
Alarm
4
5
6
1
2
3
5 mm 
(0.2 in)