ICP-CC488 | Installation Guide | 3.0  
System Operations 
EN | 16 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
The indicators for any zones that are programmed to 
be automatically isolated in STAY Mode 2 flash until 
the Exit Time expires. At the end of Exit Time, the 
zone indicators are extinguished and the codepad 
sounds one short beep. 
If a zone is not sealed at the end of Exit Time, the 
zone is automatically isolated and is lit constantly on 
the remote codepad. The zone becomes an active 
part of the system again as soon as it is resealed. For 
example, if a window is open when Exit Time 
expires, the window does not become an active part 
of the system until it is closed. Opening the window 
after Exit Time expires causes an alarm. 
Forced Arming 
Arming the system when a zone is not sealed is 
known as forced arming. Refer to Section 14.3.7 Zone 
Options 2
 on page 63 to enable forced arming for 
each zone. 
If the STAY indicator does not light and a long beep 
sounds when attempting to arm the system, forced 
arming is not permitted. If this is the case, you must 
seal all zones or manually isolate them before you 
can arm the system. 
3.6 
Disarming the System from STAY 
Mode 2 
There are two methods to disarm the system from 
STAY Mode 2. You can always use the first method. 
You can use method two only if Option 4 is enabled 
in Location 497 (refer to Section 18.6 Consumer 
Options 2 
on page 83). 
To disarm the system from STAY Mode 2 
(method one): 
1.  Enter your code and press [STAY]. 
2.  Two beeps sound and the STAY indicator is 
extinguished. The system is now disarmed. 
To disarm the system from STAY Mode 2 
(method two): 
A flashing zone indicator represents a previous alarm 
in that zone. If this is the case, a valid User Code is 
required to disarm the system using method one. To 
enable method two, Option 4 in Location 497 must 
be enabled (refer to Section 18.6 Consumer Options 2 on 
page 83). 
1.  Press and hold [0]. 
2.  When two beeps sound, release the button. 
The STAY indicator is extinguished and the 
system is disarmed. 
 
Single button disarming from STAY 
Mode 2 reports as User Code16. 
 
 
 
 
3.7 
Codepad Duress Alarm 
Figure 6:  ICP-CP500PW LED Codepad 
Showing Audible Alarm Buttons 
 
A codepad Duress Alarm is used as a silent holdup 
alarm when 9 is added to the end of a valid User 
Code being used to disarm the system. If a User 
Code has a priority level that allows arming only, 
that User Code can transmit a Duress Alarm when 
the system is armed. 
A Duress Alarm (Contact ID Event Code 121) is 
useful only if your system reports to a monitoring 
station or pocket pager because domestic reporting 
format cannot decipher the type of alarm that 
occurred. You can disable the codepad Duress Alarm 
Report by programming 0 in Location 394 (refer to 
Section 15.15 Codepad Duress Report). You can select 
Option 2 in Location 498 to use 3 instead of 9 to 
activate a Duress Alarm (refer to Section 18.7 
Consumer Options 3 
on page 83). 
3.8 Codepad 
Panic 
Alarm 
An audible codepad Panic Alarm activates when a 
user presses either [1] and [3] or [STAY] and 
[AWAY] simultaneously.   
Select Option 1 in Location 493 to program the 
codepad Panic Alarm as silent (refer to Section 18.2 
System Options 2 
on page 81). To disable the codepad 
Panic Alarm Report, program Locations 405 and 406 
to 0 (refer to Section 15.16 Codepad Panic Report on 
page 66). A codepad Panic Alarm transmits Contact 
ID Event Code 120 if the system reports to a base 
station receiver.