Bosch ICP-CC488 User Manual

Page of 118
ICP-CC488 | Installation Guide | 6.0  
Remote Arming by Telephone 
EN | 34 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
To determine the area to which the codepad 
belongs: 
1.  Press and hold [8] until two beeps sound. 
A zone indicator lights to show the area to which 
the codepad belongs. 
Zone 1 = Area 1 codepad 
Zone 2 = Area 2 codepad 
Zone 7 = Master Partitioned Codepad 
If no zone indicator lights, the codepad is set up 
incorrectly or an incorrect codepad is used. 
2.  Press [AWAY] to exit from this mode. 
5.4.12 
Send Test Report 
Holding down [9] until two beeps sound transmits a 
Test Report (Contact ID Event Code 602) to test the 
dialing and reporting capabilities of the system 
without activating the sirens. 
6.0   Remote Arming by 
Telephone 
This feature allows you to arm your system from any 
remote location by telephone. For obvious security 
reasons, you cannot disarm the system using this 
method. A touch-tone telephone is required to use 
this feature. 
To remotely arm your system by telephone: 
1.  Call the telephone number to which your control 
panel is connected. 
When the control panel answers the incoming 
call, a short jingle sounds.  
 
If you hear several strange sounding tones 
when the control panel answers the 
incoming call, the system is programmed 
for remote programming functions. Wait 
for a pause in the tones and follow Step 2 
to arm the system remotely. 
2.  Hold the phone controller to the telephone’s 
mouthpiece and press and hold the button on the 
side of the unit for 3 sec.  
You can alternatively press and hold [*] on the 
touch-tone telephone for 3 sec to arm the system. 
Two beeps sound to indicate that the system is 
armed in AWAY Mode. 
3.  Hang up the telephone. 
The system remains armed. 
If the control panel does not answer the call, the 
system might be armed already, remote functions are 
not enabled, or the ring count is set to 0. To enable 
remote arming by telephone, select Option 2 in 
Location 177 (refer to Section 12.1 Dialer Options 1 on 
page 52). To set the number of rings before the 
control panel answers, refer to Section 11.10 Ring 
Count
 on page 51
 
 
 
When both Remote Arming and 
Upload/Download are selected, the 
control panel answers the call expecting 
the remote computer. When this occurs, 
modem negotiating tones sound rather 
than the remote arming jingle. 
Using this method with a partitioned 
ICP-CC488 Control Panel arms both 
areas in AWAY Mode. Arming individual 
areas is not available with this method. 
7.0   Programming 
The control panel programming options are stored in 
a non-volatile EPROM. This memory holds all 
relevant configuration and user-specific data even 
after a total power loss.  
Because the data retention time is up to ten years 
without power, no reprogramming is required after 
powering down the control panel. 
You can change data as many times as required 
without additional specialized equipment. The 
memory is organized in locations, each of which 
holds the data for a specific function. 
 
The maximum value you can program into 
any location is 15. 
In general, the entire programming sequence consists 
of selecting the required location, and then entering 
or changing the current data. Repeat this procedure 
until you program all required data. The factory 
default settings are selected for reporting to the 
monitoring station in Contact ID format. 
The Installer Code provides access only to the 
Installer’s Programming Mode and does not allow 
you to arm and disarm the system. You cannot enter 
Installer’s Programming Mode when the system is 
armed, or at any time during siren run time. 
You can program the ICP-CC488 Control Panel 
using any of these devices: 
•  Remote codepad 
•  CC816 Alarm Link Upload/Download Software 
7.1 
Programming with the Remote 
Codepad 
To program the control panel using the remote 
codepad, the system must be disarmed with no alarm 
memory present.   
To access Installer’s Programming Mode: 
Enter the four-digit Installer Code (the factory default 
is 1234) and press [AWAY].  
Two beeps sound and both the AWAY and the 
STAY
 
indicators flash simultaneously to indicate that 
you entered Installer’s Programming Mode.