Bosch ICP-CC488 User Manual

Page of 118
ICP-CC488 | Installation Guide | 7.0  
Programming 
EN | 37 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
3.  Enter [9 5 9 #]. 
Two beeps sound after a successful test of the 
programming key. A long beep indicates that the 
programming key data is corrupt and must be 
erased to clear the corrupt data. Refer to Section 
7.4.6
 on page 38 for more information. 
4.  Enter [9 6 0 #] to exit from Installer’s 
Programming Mode.  
Two beeps sound. The STAY and AWAY 
indicators are extinguished on the remote 
codepad and the system returns to the disarmed 
state. 
5.  Remove the programming key from the control 
panel. 
Failure to exit from Installer’s Programming 
Mode before removing the programming key 
can corrupt the data in the programming key. 
7.4.2 
Command 960 – Exit from Installer's 
Programming Mode 
This command exits from Installer’s Programming 
Mode. You can exit from Installer’s Programming 
Mode from any location. 
To exit from Installer’s Programming Mode: 
Enter [9 6 0 #].  
Two beeps sound and the system returns to the 
disarmed state. When using the remote codepad, the 
STAY and AWAY indicators are extinguished. 
7.4.3 
Command 961 – Reset the Control 
Panel to Factory Default Settings 
This command resets the control panel to factory 
default values. Default values are listed throughout 
this guide and in the programming sheets in 
Section 25.0  
Programming Sheets on page 101. You 
can reset the control panel from any location.  
To reset the control panel to factory defaults: 
1.  Enter the Installer Code (the default is 1234) and 
press [#] to enter Installer’s Programming Mode. 
Two beeps sound and the STAY and AWAY 
indicators flash on the remote codepad to 
indicate that you entered Installer’s 
Programming Mode. The remote codepad 
displays the data stored in Location 000. 
2.  Enter [9 6 1 #].  
Two beeps sound and the system is reset to the 
factory default values. 
7.4.4 
Command 962 – Copy the Control 
Panel Memory to the Programming Key 
This command copies the control panel memory to 
the programming key. You can only use the CC891 
Programming Key with the ICP-CC488 Control 
Panel. 
 
 
 
To copy the control panel memory to the 
programming key: 
1.  Enter the Installer Code (the default is 1234) and 
press [#] to enter Installer’s Programming Mode. 
Two beeps sound and the STAY and AWAY 
indicators flash on the remote codepad to 
indicate you entered Installer’s Programming 
Mode. The remote codepad displays the data 
stored in Location 000. 
2.  Connect the programming key to the 
PROGRAMMING KEY pins (next to the 
Auxiliary Module socket) at the top of the 
control panel found printed circuit board. 
3.  Enter [9 6 2 #]. 
Two beeps sound after the control panel 
memory is successfully copied to the 
programming key. A long beep indicates that the 
programming key is corrupt and must be erased 
to clear the corrupt data. Refer to Section 7.4.6 
Command 964 – Erase the Programming Key 
on page 
38 for more information. 
4.  Enter command [9 6 0 #] to exit from Installer’s 
Programming Mode.  
The STAY and AWAY indicators are 
extinguished on the remote codepad to indicate 
the system is disarmed. 
5.  Remove the programming key from the control 
panel. 
Failure to exit from Installer’s Programming 
Mode before removing the programming key 
can corrupt the programming key. 
7.4.5 
Command 963 – Copy the 
Programming Key to the Control Panel 
This command copies data from the programming 
key to the control panel. You can use the CC891 
Programming Key only with the ICP-CC488 Control 
Panel. 
To copy the programming key memory to the 
control panel: 
1.  Enter the Installer Code (the default is 1234) and 
press [#] to enter Installer’s Programming Mode. 
Two beeps sound and the STAY and AWAY 
indicators flash on the remote codepad to 
indicate you entered Installer’s Programming 
Mode. The remote codepad displays the data 
stored in Location 000. 
2.  Connect the programming key to the 
PROGRAMMING KEY pins (next to the 
Auxiliary Module socket) at the top of the 
control panel printed circuit board.