ICP-CC488 | Installation Guide | 14.0  
Zone Information 
EN | 58 
 
 
Bosch Security Systems, Inc. | 12/08 | F01U089457-02 
 
 
Figure 13: Split EOL Resistors Using Two N/O 
Contacts 
 
 
1 – +12 V 
2 – Zone Input 
3 – Zone 
4 – EOL 3k3 
5 – EOL 6K8 
6 – EOL 1K5 
7 – EOL 4K7 
8 – N/O 
14.3 Zone 
Programming 
The programming information for each zone is 
stored in seven locations divided into three groups. 
The first three locations determine how the zone 
operates, the next two locations set up a number of 
zone options, and the last two locations store the 
dialer reporting information for the zone. 
Zone Operating Information 
These locations store the Zone Type (for example, 
Delay-1, Instant, or 24-Hour), the Zone Pulse Count, 
and the Zone Pulse Count Time. The Zone Pulse 
Count specifies the number of times the zone must 
activate within the time specified in the Zone Pulse 
Count Time. Refer to Sections 14.3.2 Zone Types
14.3.3 Zone Pulse Count, and 14.3.4 Zone Pulse Count 
Time
 on pages 59 through 61 for more information. 
Zone Options 
These two locations allow you to select from a 
number of options. Refer to Sections 14.3.5 Zone 
Options 1
 on page 61 and 14.3.7 Zone Options 2 on 
page 63 for more information. 
Zone Reporting Information 
This information includes the locations for the Zone 
Report Code and the Zone Dialer Options.  
The Zone Report Code determines if the control 
panel sends Alarm Reports for the zone. Refer to 
Section 14.3.8 Zone Report Code on page 64 for more 
information. 
 
The Zone Dialer Options location enables you to 
specify how a zone reports to a base station receiver. 
Refer to Section 14.3.9 Zone Dialer Options on page 64 
for more information. 
14.3.1 ICP-CC488 
Zone 
Defaults 
Location
267 to 378 
 
Location Default 
Zone #01 (Default = Delay–1) 
 
 
Zone Type  267 
Zone Pulse Count  268 
Zone Pulse Count Time  269 
Zone Options 1  270 
Zone Options 2  271 
14 
Report Code  272 
Dialer Options  273 
Zone #02 (Default = Handover) 
 
 
Zone Type  274 
Zone Pulse Count  275 
Zone Pulse Count Time  276 
Zone Options 1  277 
Zone Options 2  278 
14 
Report Code  279 
Dialer Options  280 
Zone #03 (Default = Handover) 
 
 
Zone Type  281 
Zone Pulse Count  282 
Zone Pulse Count Time  283 
Zone Options 1  284 
Zone Options 2  285 
14 
Report Code  286 
Dialer Options  287 
Zone #04 (Default = Handover) 
 
 
Zone Type  288 
Zone Pulse Count  289 
Zone Pulse Count Time  290 
Zone Options 1  291 
Zone Options 2  292 
14 
Report Code  293 
Dialer Options  294 
Zone #05 (Default = Instant) 
 
 
Zone Type  295 
Zone Pulse Count  296 
Zone Pulse Count Time  297 
Zone Options 1  298 
Zone Options 2  299 
14 
Report Code  300 
Dialer Options  301 
Zone #06 (Default = Instant) 
 
 
Zone Type  302 
Zone Pulse Count  303 
Zone Pulse Count Time  304 
Zone Options 1  305 
Zone Options 2  306 
14 
Report Code  307 
Dialer Options  308